    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 12:43:06 on February 8, 2010

    Entry number 309179

    keyword=End_of_Parity_Run_1116__CODA_Config=Prex
    ************************************************
     Run Number: 1116
     End of Run Comment:
    
    Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 240Hz - Long Run with healthy LED-PMT signals. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1116 at Mon Feb  8 12:42:51 EST 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : 240 Hz Line Sync
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Octet
    Helicity Clock Read                      : 240 Hz Line Sync
    Helicity Settle Read                     : 100
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Octet
    Helicity Frequency                       : 240
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 26mW
    Calculated power in cavity               : 0.186891
    Photodiode on table                      : 0.449153
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : -108.937
    Laser X position on QPD 2                : -1315.68
    Laser Y position on QPD 2                : 442.478
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : -0.00122085
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -5665[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2713
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0494415
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : 6.20949
    Calculated polarisation in cavity        : 11.4229
    Photodiode 1 after Wollaston prism       : 0.00800535
    Photodiode 2 after Wollaston prism       : 0.00636396
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.00073381
    Left Arm Q1 gauss meter                  : 0.0002621
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000396842
    Left Arm Q2 momentum                     : -9.21604e-07
    Left Arm Q2 gauss meter                  : 0.0010595
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00376391
    Left Arm D1 momentum                     : 0.00252373
    Left Arm D1 NMR                          : 0.270058
    Left Arm Q3 power supply current         : -0.000428816
    Left Arm Q3 momentum                     : -1.25662e-06
    Left Arm Q3 gauss meter                  : -0.00012386
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00178685
    Right Arm Q1 gauss meter                 : -5.37e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000103527
    Right Arm Q2 momentum                    : -2.40555e-07
    Right Arm Q2 gauss meter                 : 0.0005371
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00326181
    Right Arm D1 momentum                    : 0.00461587
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : 0.000156925
    Right Arm Q3 momentum                    : 0.00188794
    Right Arm Q3 gauss meter                 : 3.75e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0229092
    Current on Unser monitor                 : 18.3451
    Current on Upstream bcm                  : 0.0334933
    Current on Downstream bcm                : 0.0123251
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0018127
    Tiefenbach Hall A energy                 : 4867.43
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 4.38137
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.9889
    pressure fill bottle H2                  : 14.8272
    pressure ballast H2                      : 25.4139
    pressure exhaust H2                      : 14.8104
    cryogen input temp                       : 299.8
    crogen return flow                       : 0.410569
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1116.log:
    
       Cumulative stats for 8301 events: 
       
       Events failing cut conditions:
       0         Low_beam   5251
       1        Beam_burp      0
       2          Evt_seq     33
       3         Pair_seq     97
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------