NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 13:11:58 on January 27, 2010
Entry number 309138
keyword=End_of_Parity_Run_1100__CODA_Config=Prex
************************************************
Run Number: 1100
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ TESTS - 240 Hz - Installing PMT on LHRS,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1100 at Wed Jan 27 13:11:47 EST 2010
CODA Configuration: Prex
Compton Run Number : 0
-----------------------------------------
Wien angle : -0
Wien BDL : 3.18799
Wien field : 60.306
Laser attenuation Hall A : 0
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.27
Gun2: PC (PITA) NEG : 6.43
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : 240 Hz Line Sync
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : 240 Hz Line Sync
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 240
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power :
Calculated power in cavity : 0.171341
Photodiode on table : 0.298106
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -163.404
Laser X position on QPD 2 : 1315.84
Laser Y position on QPD 2 : -442.532
QPD 1 sum : -0.00366241
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : 7320[c]
Position set point for adjustable
mirror 2 (either x or y) : 15670[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point :
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0506622
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -3.56894
Calculated polarisation in cavity : 9.53129
Photodiode 1 after Wollaston prism : 0.00741633
Photodiode 2 after Wollaston prism : 0.00643547
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000744762
Left Arm Q1 gauss meter : 0.0002742
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000509156
Left Arm Q2 momentum : -1.01724e-06
Left Arm Q2 gauss meter : 0.0010429
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00332783
Left Arm D1 momentum : 0.00254739
Left Arm D1 NMR : 0.27036
Left Arm Q3 power supply current : -0.000342301
Left Arm Q3 momentum : -8.59795e-07
Left Arm Q3 gauss meter : -0.00011774
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00146341
Right Arm Q1 gauss meter : -4.76e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.00018487
Right Arm Q2 momentum : -4.29563e-07
Right Arm Q2 gauss meter : 0.0005313
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00370307
Right Arm D1 momentum : 0.0046592
Right Arm D1 NMR : 0.453959
Right Arm Q3 power supply current : -5.97809e-05
Right Arm Q3 momentum : -1.50238e-07
Right Arm Q3 gauss meter : 6.78e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0234922
Current on Unser monitor : 17.506
Current on Upstream bcm : 0.0339951
Current on Downstream bcm : 0.0129303
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00623125
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : -0
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.8577
pressure fill bottle H2 : 14.7158
pressure ballast H2 : 25.5955
pressure exhaust H2 : 14.9096
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.3398
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1100.log:
Cumulative stats for 100651 events:
Events failing cut conditions:
0 Low_beam 65101
1 Beam_burp 0
2 Evt_seq 375
3 Pair_seq 1
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------