    User name apar

    Log entry time 13:54:49 on January 26, 2010

    Entry number 309110

    keyword=End_of_Parity_Run_1088__CODA_Config=Prex
    keyword=End_of_Parity_Run_1087__CODA_Config=Prex
    keyword=End_of_Parity_Run_1089__CODA_Config=Prex
    keyword=End_of_Parity_Run_1086__CODA_Config=Prex
    ************************************************
     Run Number: 1087
     End of Run Comment:
    
    Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 30Hz - Long Run with healthy LED-PMT signal. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1087 at Tue Jan 26 13:54:18 EST 2010
    CODA Configuration: Prex
    
    
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : -0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.169647
    Photodiode on table                      : 0.281406
    Laser X position on QPD 1                : -110.919
    Laser Y position on QPD 1                : -81.7031
    Laser X position on QPD 2                : 1315.84
    Laser Y position on QPD 2                : -442.532
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : 0.0012207
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 7320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 15670[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0506622
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -3.89855
    Calculated polarisation in cavity        : 9.21045
    Photodiode 1 after Wollaston prism       : 0.00728246
    Photodiode 2 after Wollaston prism       : 0.00624479
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000566395
    Left Arm Q1 gauss meter                  : 0.0002779
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000554082
    Left Arm Q2 momentum                     : -9.56381e-07
    Left Arm Q2 gauss meter                  : 0.0010301
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00337787
    Left Arm D1 momentum                     : 0.00253598
    Left Arm D1 NMR                          : 0.270324
    Left Arm Q3 power supply current         : -0.00036487
    Left Arm Q3 momentum                     : -9.16485e-07
    Left Arm Q3 gauss meter                  : -0.000118
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00243372
    Right Arm Q1 gauss meter                 : -6.02e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000162685
    Right Arm Q2 momentum                    : -4.55336e-07
    Right Arm Q2 gauss meter                 : 0.0005272
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00356187
    Right Arm D1 momentum                    : 0.00464557
    Right Arm D1 NMR                         : 0.190642
    Right Arm Q3 power supply current        : 0
    Right Arm Q3 momentum                    : 0.00205754
    Right Arm Q3 gauss meter                 : 6.7e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0231478
    Current on Unser monitor                 : 17.0723
    Current on Upstream bcm                  : 0.0330547
    Current on Downstream bcm                : 0.0132409
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00648897
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : -0
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.6792
    pressure fill bottle H2                  : 14.5266
    pressure ballast H2                      : 25.4124
    pressure exhaust H2                      : 14.6593
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1087.log:
    
       Cumulative stats for 282 events: 
       
       Events failing cut conditions:
       0         Low_beam    282
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------
    
    

    ************************************************ Run Number: 1088 End of Run Comment:
    Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 30Hz - Long Run with healthy LED-PMT signal. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1088 at Tue Jan 26 13:54:17 EST 2010
    CODA Configuration: Prex
    
    
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : -0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.169647
    Photodiode on table                      : 0.281406
    Laser X position on QPD 1                : -110.919
    Laser Y position on QPD 1                : -81.7031
    Laser X position on QPD 2                : 1315.84
    Laser Y position on QPD 2                : -442.532
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : 0.0012207
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 7320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 15670[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0506622
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -3.89855
    Calculated polarisation in cavity        : 9.21045
    Photodiode 1 after Wollaston prism       : 0.00728246
    Photodiode 2 after Wollaston prism       : 0.00624479
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000566395
    Left Arm Q1 gauss meter                  : 0.0002779
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000554082
    Left Arm Q2 momentum                     : -9.56381e-07
    Left Arm Q2 gauss meter                  : 0.0010301
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00337787
    Left Arm D1 momentum                     : 0.00253598
    Left Arm D1 NMR                          : 0.270324
    Left Arm Q3 power supply current         : -0.00036487
    Left Arm Q3 momentum                     : -9.16485e-07
    Left Arm Q3 gauss meter                  : -0.000118
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00243372
    Right Arm Q1 gauss meter                 : -6.02e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000162685
    Right Arm Q2 momentum                    : -4.55336e-07
    Right Arm Q2 gauss meter                 : 0.0005272
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00356187
    Right Arm D1 momentum                    : 0.00464557
    Right Arm D1 NMR                         : 0.190642
    Right Arm Q3 power supply current        : 0
    Right Arm Q3 momentum                    : 0.00205754
    Right Arm Q3 gauss meter                 : 6.7e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0231478
    Current on Unser monitor                 : 17.0723
    Current on Upstream bcm                  : 0.0330547
    Current on Downstream bcm                : 0.0132409
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00648897
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : -0
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.6792
    pressure fill bottle H2                  : 14.5266
    pressure ballast H2                      : 25.4124
    pressure exhaust H2                      : 14.6593
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1088.log:
    
       Cumulative stats for 56185 events: 
       
       Events failing cut conditions:
       0         Low_beam  55885
       1        Beam_burp      0
       2          Evt_seq      3
       3         Pair_seq      7
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------
    
    
    ************************************************ Run Number: 1089 End of Run Comment:
    Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 30Hz - Long Run with healthy LED-PMT signal. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1089 at Tue Jan 26 13:54:16 EST 2010
    CODA Configuration: Prex
    
    
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : -0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.169647
    Photodiode on table                      : 0.281406
    Laser X position on QPD 1                : -110.919
    Laser Y position on QPD 1                : -81.7031
    Laser X position on QPD 2                : 1315.84
    Laser Y position on QPD 2                : -442.532
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : 0.0012207
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 7320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 15670[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0506622
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -3.89855
    Calculated polarisation in cavity        : 9.21045
    Photodiode 1 after Wollaston prism       : 0.00728246
    Photodiode 2 after Wollaston prism       : 0.00624479
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000566395
    Left Arm Q1 gauss meter                  : 0.0002779
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000554082
    Left Arm Q2 momentum                     : -9.56381e-07
    Left Arm Q2 gauss meter                  : 0.0010301
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00337787
    Left Arm D1 momentum                     : 0.00253598
    Left Arm D1 NMR                          : 0.270324
    Left Arm Q3 power supply current         : -0.00036487
    Left Arm Q3 momentum                     : -9.16485e-07
    Left Arm Q3 gauss meter                  : -0.000118
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00243372
    Right Arm Q1 gauss meter                 : -6.02e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000162685
    Right Arm Q2 momentum                    : -3.78015e-07
    Right Arm Q2 gauss meter                 : 0.0005272
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00356187
    Right Arm D1 momentum                    : 0.00464557
    Right Arm D1 NMR                         : 0.190642
    Right Arm Q3 power supply current        : 0
    Right Arm Q3 momentum                    : 0.00205754
    Right Arm Q3 gauss meter                 : 6.7e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0231478
    Current on Unser monitor                 : 17.0723
    Current on Upstream bcm                  : 0.0330547
    Current on Downstream bcm                : 0.0132409
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00648897
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : -0
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.6792
    pressure fill bottle H2                  : 14.5373
    pressure ballast H2                      : 25.4124
    pressure exhaust H2                      : 14.6593
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1089.log:
    
       Cumulative stats for 100593 events: 
       
       Events failing cut conditions:
       0         Low_beam  67093
       1        Beam_burp      0
       2          Evt_seq    766
       3         Pair_seq   6735
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------
    
    

    ************************************************ Run Number: 1086 End of Run Comment:
    Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 30Hz - Long Run with healthy LED-PMT signal. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1086 at Tue Jan 26 13:54:21 EST 2010
    CODA Configuration: Prex
    
    
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : -0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.168743
    Photodiode on table                      : 0.281406
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : 326.784
    Laser X position on QPD 2                : -7.18596e+06
    Laser Y position on QPD 2                : -442.532
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : -7.45058e-08
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 7320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 15670[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0494415
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 4.52481
    Calculated polarisation in cavity        : 7.67101
    Photodiode 1 after Wollaston prism       : 0.00728246
    Photodiode 2 after Wollaston prism       : 0.00624479
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000486599
    Left Arm Q1 gauss meter                  : 0.0002747
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000554082
    Left Arm Q2 momentum                     : -1.28677e-06
    Left Arm Q2 gauss meter                  : 0.0010564
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00338144
    Left Arm D1 momentum                     : 0.00253598
    Left Arm D1 NMR                          : 0.270324
    Left Arm Q3 power supply current         : -0.000537901
    Left Arm Q3 momentum                     : -9.16485e-07
    Left Arm Q3 gauss meter                  : -0.000118
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.0021315
    Right Arm Q1 gauss meter                 : -6.02e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000162685
    Right Arm Q2 momentum                    : -3.78015e-07
    Right Arm Q2 gauss meter                 : 0.000534
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00352656
    Right Arm D1 momentum                    : 0.00464557
    Right Arm D1 NMR                         : 0.190642
    Right Arm Q3 power supply current        : -0.000123298
    Right Arm Q3 momentum                    : -3.09865e-07
    Right Arm Q3 gauss meter                 : 6.7e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0230333
    Current on Unser monitor                 : 17.0723
    Current on Upstream bcm                  : 0.0328257
    Current on Downstream bcm                : 0.0132409
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00648897
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : -0
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.6593
    pressure fill bottle H2                  : 14.5266
    pressure ballast H2                      : 25.3956
    pressure exhaust H2                      : 14.6136
    cryogen input temp                       : 299.8
    crogen return flow                       : 0.111353
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1086.log:
    
       Cumulative stats for 28944 events: 
       
       Events failing cut conditions:
       0         Low_beam  28944
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------